Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 40
Filter
1.
Expert Rev Med Devices ; 20(1): 5-16, 2023 Jan.
Article in English | MEDLINE | ID: covidwho-2230996

ABSTRACT

INTRODUCTION: Whole blood samples, including arterial, venous, and capillary blood, are regularly used for disease diagnosis and monitoring. The global Covid-19 pandemic has highlighted the need for a more resilient screening capacity. Minimally invasive sampling techniques, such as capillary blood sampling, are routinely used for point of care testing in the home healthcare setting and clinical settings such as the Intensive Care Unit with less pain and wounding than conventional venepuncture. AREAS COVERED: In this manuscript, we aim to provide a overview of state-of-the-art of techniques for obtaining samples of capillary blood. We first review both established and novel methods for releasing blood from capillaries in the skin. Next, we provide a comparison of different capillary blood sampling methods based on their mechanism, testing site, puncture size, cost, wound geometry, healing, and perceptions of pain. Finally, we overview established and new methods for enhancing capillary blood collection. EXPERT OPINION: We expect that microneedles will prove to be a preferred option for paediatric blood collection. The ability of microneedles to collect a capillary blood sample without pain will improve paediatric healthcare outcomes. Jet injection may prove to be a useful method for facilitating both blood collection and drug delivery.


Subject(s)
COVID-19 , Pandemics , Humans , Child , Blood Specimen Collection/methods , Veins , Point-of-Care Testing , Capillaries
2.
BMC Health Serv Res ; 22(1): 1470, 2022 Dec 02.
Article in English | MEDLINE | ID: covidwho-2153581

ABSTRACT

BACKGROUND: The goal of the study was to investigate patients' with systemic rheumatic diseases and healthcare professionals' experiences and preferences regarding self-sampling of capillary blood in rheumatology care. METHODS: Patients performed a supervised and consecutive unsupervised capillary blood self-collection using an upper arm based device. Subsequently, patients (n = 15) and their attending health care professionals (n = 5) participated in an explorative, qualitative study using problem-centered, telephone interviews. Interview data were analyzed using structured qualitative content analysis. RESULTS: Interviewed patients reported easy application and high usability. Patients and health care professionals alike reported time and cost savings, increased independence and flexibility, improved monitoring and reduction of risk of infection during Covid-19 as benefits. Reported drawbacks include limited blood volume, limited usability in case of functional restrictions, and environmental concerns. Older, immobile patients with long journeys to traditional blood collection sites and young patients with little time to spare for traditional blood collection appointments could be user groups, likely to benefit from self-sampling services. CONCLUSIONS: At-home blood self-sampling could effectively complement current rheumatology telehealth care. Appropriateness and value of this service needs to be carefully discussed with patients on an individual basis. TRIAL REGISTRATION: WHO International Clinical Trials Registry: DRKS00024925. Registered on 15/04/2021.


Subject(s)
COVID-19 , Rheumatology , Humans , Qualitative Research , Health Personnel , Blood Specimen Collection
3.
PLoS One ; 17(8): e0272572, 2022.
Article in English | MEDLINE | ID: covidwho-1987158

ABSTRACT

BACKGROUND: Venous phlebotomy performed by trained personnel is critical for patient diagnosis and monitoring of chronic disease, but has limitations in resource-constrained settings, and represents an infection control challenge during outbreaks. Self-collection devices have the potential to shift phlebotomy closer to the point of care, supporting telemedicine strategies and virtual clinical trials. Here we assess a capillary blood micro-sampling device, the Tasso Serum Separator Tube (SST), for measuring blood protein levels in healthy subjects and non-hospitalized COVID-19 patients. METHODS: 57 healthy controls and 56 participants with mild/moderate COVID-19 were recruited at two U.S. military healthcare facilities. Healthy controls donated Tasso SST capillary serum, venous plasma and venous serum samples at multiple time points, while COVID-19 patients donated a single Tasso SST serum sample at enrolment. Concentrations of 17 protein inflammatory biomarkers were measured in all biospecimens by Ella multi-analyte immune-assay. RESULTS: Tasso SST serum protein measurements in healthy control subjects were highly reproducible, but their agreements with matched venous samples varied. Most of the selected proteins, including CRP, Ferritin, IL-6 and PCT, were well-correlated between Tasso SST and venous serum with little sample type bias, but concentrations of D-dimer, IL-1B and IL-1Ra were not. Self-collection at home with delayed sample processing was associated with significant concentrations differences for several analytes compared to supervised, in-clinic collection with rapid processing. Finally, Tasso SST serum protein concentrations were significantly elevated in in non-hospitalized COVID-19 patients compared with healthy controls. CONCLUSIONS: Self-collection of capillary blood with micro-sampling devices provides an attractive alternative to routine phlebotomy. However, concentrations of certain analytes may differ significantly from those in venous samples, and factors including user proficiency, temperature control and time lags between specimen collection and processing need to be considered for their effect on sample quality and reproducibility.


Subject(s)
COVID-19 , Blood Proteins , Blood Specimen Collection , COVID-19/diagnosis , Healthy Volunteers , Humans , Reproducibility of Results , Specimen Handling
6.
PLoS One ; 16(9): e0257560, 2021.
Article in English | MEDLINE | ID: covidwho-1430541

ABSTRACT

Certain clinical indications and treatments such as the use of rasburicase in cancer therapy and 8-aminoquinolines for Plasmodium vivax malaria treatment would benefit from a point-of-care test for glucose-6-phosphate dehydrogenase (G6PD) deficiency. Three studies were conducted to evaluate the performance of one such test: the STANDARD™ G6PD Test (SD BIOSENSOR, South Korea). First, biological interference on the test performance was evaluated in specimens with common blood disorders, including high white blood cell (WBC) counts. Second, the test precision on fingerstick specimens was evaluated against five individuals of each, deficient, intermediate, and normal G6PD activity status. Third, clinical performance of the test was evaluated at three point-of-care settings in the United States. The test performed equivalently to the reference assay in specimens with common blood disorders. High WBC count blood samples resulted in overestimation of G6PD activity in both the reference assay and the STANDARD G6PD Test. The STANDARD G6PD Test showed good precision on multiple fingerstick specimens from the same individual. The same G6PD threshold values (U/g Hb) were applied for a semiquantitative interpretation for fingerstick- and venous-derived results. The sensitivity/specificity values (95% confidence intervals) for the test for G6PD deficiency were 100 (92.3-100.0)/97 (95.2-98.2) and 100 (95.7-100.0)/97.4 (95.7-98.5) for venous and capillary specimens, respectively. The same values for females with intermediate (> 30% to ≤ 70%) G6PD activity were 94.1 (71.3-99.9)/88.2 (83.9-91.7) and 82.4 (56.6-96.2)/87.6(83.3-91.2) for venous and capillary specimens, respectively. The STANDARD G6PD Test enables point-of-care testing for G6PD deficiency.


Subject(s)
Glucosephosphate Dehydrogenase Deficiency/diagnosis , Glucosephosphate Dehydrogenase/blood , Point-of-Care Systems/standards , Adolescent , Adult , Aged , Blood Specimen Collection , Child , Child, Preschool , Female , Glucosephosphate Dehydrogenase/genetics , Glucosephosphate Dehydrogenase/standards , Glucosephosphate Dehydrogenase Deficiency/complications , Hematologic Diseases/complications , Hemoglobins/analysis , Humans , Leukocyte Count , Male , Middle Aged , Reagent Kits, Diagnostic , Reference Standards , Sensitivity and Specificity , Young Adult
7.
Transfusion ; 61(10): 2814-2824, 2021 10.
Article in English | MEDLINE | ID: covidwho-1402980

ABSTRACT

In March 2020, there were no treatment options for COVID-19. Passive immune therapy including anti-SARS-CoV-2 hyperimmune globulin (hIVIG) was a logical candidate for COVID-19 therapeutic trials, given past success treating emerging pathogens with endogenous neutralizing antibodies. We established a plasma collection protocol for persons recovered from COVID-19. To speed recruitment in the first U.S. hotspot, Seattle, Washington, federal and state public health agencies collaborated with Bloodworks Northwest to collect convalescent plasma (CP) for manufacturing hIVIG. During March-December 2020, we identified and recruited prospective CP donors via letters to persons recovered from COVID-19 with laboratory-confirmed SARS-CoV-2 infection. Prospective donors were pre-screened and administered a medical history survey. Anti-SARS-CoV-2 neutralizing antibody (NAb) titers were classified as qualifying (≥1:80) or non-qualifying (<1:80) for enrollment based on a live virus neutralization assay. Generalized estimating equations were used to identify characteristics of donors associated with qualifying versus nonqualifying NAb titers. Overall, 21,359 letters resulted in 3207 inquiries, 2159 prescreenings with laboratory-confirmed SARS-CoV-2 infection, and 573 donors (27% of all pre-screenings with confirmed infection) who provided a screening plasma donation. Of 573 donors screened, 254 (44%) provided plasma with qualifying NAb titers, resulting in 1284 units for hIVIG manufacture. In a multivariable model, after adjusting for other factors, time (60 days) from COVID-19 symptom onset to screening was associated with lower odds of qualifying NAb (adjusted odds ratio = 0.67, 95% CI: 0.48-0.94). The collaboration facilitated a rapid response to develop and provide hIVIG for clinical trials and CP for transfusion. Only 1 in 12 donor inquiries resulted in a qualifying plasma donation. Challenges included recruitment and the relatively low percentage of persons with high NAb titers and limited screening capacity. This resource-intensive collaboration may not be scalable but informs preparedness and response strategies for plasma collection in future epidemics. Operational readiness plans with templates for screening, consent, and data collection forms are recommended.


Subject(s)
Blood Specimen Collection , COVID-19/therapy , Public Health , Public-Private Sector Partnerships , SARS-CoV-2 , Adult , Aged , Aged, 80 and over , Emergencies , Female , Humans , Immunization, Passive , Male , Middle Aged , Young Adult , COVID-19 Serotherapy
8.
PLoS One ; 16(9): e0255841, 2021.
Article in English | MEDLINE | ID: covidwho-1394541

ABSTRACT

BACKGROUND: Efforts to minimize COVID-19 exposure during the current SARS-CoV-2 pandemic have led to limitations in access to medical care and testing. The Tasso-SST kit includes all of the components necessary for remote, capillary blood self-collection. In this study, we sought to investigate the accuracy and reliability of the Tasso-SST device as a self-collection device for measurement of SARS-CoV-2 IgG antibodies. METHODS: Capillary blood was obtained via unsupervised and supervised application of the Tasso-SST device, and venous blood was collected by standard venipuncture. Unsupervised self-collected blood samples underwent either extreme summer or winter-simulated shipping conditions prior to testing. Sera obtained by all three methods were tested concurrently using the EuroImmun anti-SARS-CoV-2 S1 IgG assay in a CLIA-certified clinical laboratory. RESULTS: Successful Tasso-SST capillary blood collection by unsupervised and supervised administration was completed by 93.4% and 94.5% of participants, respectively. Sera from 56 participants, 55 with documented (PCR+) COVID-19, and 33 healthy controls were then tested for anti-SARS-CoV-2 IgG antibodies. Compared to venous blood results, Tasso-SST-collected (unstressed) and the summer- and winter-stressed blood samples demonstrated Deming regression slopes of 1.00 (95% CI: 0.99-1.02), 1.00 (95% CI: 0.98-1.01), and 0.99 (95% CI: 0.97-1.01), respectively, with an overall accuracy of 98.9%. CONCLUSIONS: Capillary blood self-collection using the Tasso-SST device had a high success rate. Moreover, excellent concordance was found for anti-SARS-CoV-2 IgG results between Tasso-SST capillary and standard venous blood-derived sera. The Tasso-SST device should enable widespread collection of capillary blood for testing without medical supervision, facilitating epidemiologic studies.


Subject(s)
Antibodies, Viral/immunology , Blood Specimen Collection/methods , COVID-19 Testing/methods , COVID-19/diagnosis , Immunoglobulin G/immunology , SARS-CoV-2/immunology , Adult , Aged , Blood Specimen Collection/instrumentation , COVID-19/epidemiology , COVID-19/virology , COVID-19 Testing/instrumentation , Female , Humans , Male , Middle Aged , Pandemics , Reproducibility of Results , SARS-CoV-2/physiology , Sensitivity and Specificity , Young Adult
9.
Bioanalysis ; 13(24): 1851-1863, 2021 Dec.
Article in English | MEDLINE | ID: covidwho-1380034

ABSTRACT

COVID-19 led to changes in the way blood samples are collected. As societies were isolated to control viral spread, access to facilities became limited. Remote sample collection with a volumetric microsampling approach, using Mitra® devices based on VAMS® technology, proved to be highly effective. It allowed people to collect high-quality samples at home and post them to a laboratory. This enabled scientists to conduct large serosurveillance studies, with results showing that seroprevalence of COVID-19 was higher than initially expected. Furthermore, remote microsampling studies by several institutions were conducted to measure the relationship between antigen levels and antibody response and duration. VAMS technology was also used in COVID-19 clinical trials. In summary, the independent research reviewed in this paper proved that VAMS is an effective sample collection alternative.


Subject(s)
COVID-19/diagnosis , Blood Specimen Collection/methods , COVID-19/epidemiology , COVID-19/virology , Dried Blood Spot Testing/methods , Humans , Population Surveillance , SARS-CoV-2/isolation & purification , Specimen Handling/methods
10.
PLoS One ; 16(8): e0256423, 2021.
Article in English | MEDLINE | ID: covidwho-1376625

ABSTRACT

BACKGROUND: Point-of-care (PoC) testing of platelet count (PLT) provides real-time data for rapid decision making. The goal of this study is to evaluate the accuracy and precision of platelet counting using a new microvolume (8 µL), absolute counting, 1.5 kg cytometry-based blood analyzer, the rHEALTH ONE (rHEALTH) in comparison with the International Society of Laboratory Hematology (ISLH) platelet method, which uses a cytometer and an impedance analyzer. METHODS: Inclusion eligibility were healthy adults (M/F) ages 18-80 for donation of fingerprick and venous blood samples. Samples were from a random N = 31 volunteers from a single U.S. site. Samples were serially diluted to test thrombocytopenic ranges. Interfering substances and conditions were tested, including RBC fragments, platelet fragments, cholesterol, triglycerides, lipids, anti-platelet antibodies, and temperature. RESULTS: The concordance between the rHEALTH and ISLH methods had a slope = 1.030 and R2 = 0.9684. The rHEALTH method showed a correlation between capillary and venous blood samples (slope = 0.9514 and R2 = 0.9684). Certain interferents changed platelet recovery: RBC fragments and anti-platelet antibodies with the ISLH method; platelet fragments and anti-platelet antibodies on the rHEALTH; and RBC fragments, platelets fragments, triglycerides and LDL on the clinical impedance analyzer. The rHEALTH's precision ranged from 3.1-8.0%, and the ISLH from 1.0-10.5%. CONCLUSIONS: The rHEALTH method provides similar results with the reference method and good correlation between adult capillary and venous blood samples. This demonstrates the ability of the rHEALTH to provide point-of-care assessment of normal and thrombocytopenic platelet counts from fingerprick blood with high precision and limited interferences.


Subject(s)
Capillaries/cytology , Flow Cytometry/instrumentation , Microtechnology/instrumentation , Point-of-Care Systems , Adolescent , Adult , Aged , Aged, 80 and over , Biological Assay , Blood Specimen Collection , Humans , Middle Aged , Platelet Count , Young Adult
11.
Adv Sci (Weinh) ; 8(18): e2100323, 2021 09.
Article in English | MEDLINE | ID: covidwho-1316190

ABSTRACT

Blood cell analysis is a major pillar of biomedical research and healthcare. These analyses are performed in central laboratories. Rapid shipment from collection site to the central laboratories is currently needed because cells and biomarkers degrade rapidly. The dried blood spot from a fingerstick allows the preservation of cellular molecules for months but entire cells are never recovered. Here leucocyte elution is optimized from dried blood spots. Flow cytometry and mRNA expression profiling are used to analyze the recovered cells. 50-70% of the leucocytes that are dried on a polyester solid support via elution after shaking the support with buffer are recovered. While red blood cells lyse upon drying, it is found that the majority of leucocytes are preserved. Leucocytes have an altered structure that is improved by adding fixative in the elution buffer. Leucocytes are permeabilized, allowing an easy staining of all cellular compartments. Common immunophenotyping and mRNAs are preserved. The ability of a new biomarker (CD169) to discriminate between patients with and without Severe Acute Respiratory Syndrome induced by Coronavirus 2 (SARS-CoV-2) infections is also preserved. Leucocytes from blood can be dried, shipped, and/or stored for at least 1 month, then recovered for a wide variety of analyses, potentially facilitating biomedical applications worldwide.


Subject(s)
Communicable Diseases/diagnosis , Diagnostic Tests, Routine/methods , Dried Blood Spot Testing/methods , Hematology/methods , Immunophenotyping/methods , Antibodies, Viral/blood , Biomarkers/blood , Blood Specimen Collection/methods , COVID-19/diagnosis , Cell Separation/methods , Communicable Diseases/virology , Erythrocytes/virology , Flow Cytometry/methods , Humans , Leukocytes/virology , RNA, Messenger/blood , SARS-CoV-2/genetics
12.
Clin Biochem ; 96: 56-62, 2021 Oct.
Article in English | MEDLINE | ID: covidwho-1305215

ABSTRACT

OBJECTIVES: Camostat mesilate is a drug that is being repurposed for new applications such as that against COVID-19 and prostate cancer. This induces a need for the development of an analytical method for the quantification of camostat and its metabolites in plasma samples. Camostat is, however, very unstable in whole blood and plasma due to its two ester bonds. The molecule is readily hydrolysed by esterases to 4-(4-guanidinobenzoyloxy)phenylacetic acid (GBPA) and further to 4-guanidinobenzoic acid (GBA). For reliable quantification of camostat, a technique is required that can instantly inhibit esterases when blood samples are collected. DESIGN AND METHODS: An ultra-high-performance liquid chromatography-tandem mass spectrometry method (UHPLC-ESI-MS/MS) using stable isotopically labelled analogues as internal standards was developed and validated. Different esterase inhibitors were tested for their ability to stop the hydrolysis of camostat ester bonds. RESULTS: Both diisopropylfluorophosphate (DFP) and paraoxon were discovered as efficient inhibitors of camostat metabolism at 10 mM concentrations. No significant changes in camostat and GBPA concentrations were observed in fluoride-citrate-DFP/paraoxon-preserved plasma after 24 h of storage at room temperature or 4 months of storage at -20 °C and -80 °C. The lower limits of quantification were 0.1 ng/mL for camostat and GBPA and 0.2 ng/mL for GBA. The mean true extraction recoveries were greater than 90%. The relative intra-laboratory reproducibility standard deviations were at a maximum of 8% at concentrations of 1-800 ng/mL. The trueness expressed as the relative bias of the test results was within ±3% at concentrations of 1-800 ng/mL. CONCLUSIONS: A methodology was developed that preserves camostat and GBPA in plasma samples and provides accurate and sensitive quantification of camostat, GBPA and GBA by UHPLC-MS/MS.


Subject(s)
Blood Specimen Collection/methods , Chromatography, High Pressure Liquid/methods , Esters/blood , Guanidines/blood , Tandem Mass Spectrometry/methods , COVID-19/blood , Enzyme Inhibitors/pharmacology , Esterases/antagonists & inhibitors , Esterases/metabolism , Esters/metabolism , Esters/pharmacology , Guanidines/pharmacology , Humans , Hydrolysis/drug effects , Isoflurophate/chemistry , Isoflurophate/pharmacology , Paraoxon/blood , Paraoxon/chemistry , Paraoxon/pharmacology , Reproducibility of Results , SARS-CoV-2/isolation & purification , COVID-19 Drug Treatment
13.
Clin Immunol ; 235: 108791, 2022 02.
Article in English | MEDLINE | ID: covidwho-1293654

ABSTRACT

Coronavirus Disease 2019 (COVID-19) emerged as a global pandemic resulting in significant mortality and morbidity. COVID-19 vaccines have been shown to be highly effective in preventing COVID-19 infections and significantly reducing disease severity and mortality. We report on a novel COVID-19 antibody assay using a unique platform to rapidly detect SARS-CoV-2 antibodies with a drop of fingerstick blood in a subject following COVID-19 vaccination. We show early detection of SARS-CoV-2 antibodies post vaccination and persistence of detectable antibodies for at least 6 months. Rapid point of care COVID-19 antibody tests might have a role in assessing the appearance and durability of immune response following COVID-19 vaccination.


Subject(s)
Antibodies, Viral/immunology , BNT162 Vaccine/immunology , Blood Specimen Collection/methods , COVID-19/immunology , Immunoglobulins/immunology , SARS-CoV-2/immunology , Antibodies, Viral/blood , BNT162 Vaccine/administration & dosage , COVID-19/epidemiology , COVID-19/virology , COVID-19 Serological Testing/methods , Fingers , Humans , Immunoglobulins/blood , Male , Middle Aged , Pandemics/prevention & control , Reproducibility of Results , SARS-CoV-2/physiology , Vaccination
14.
PLoS One ; 16(6): e0252306, 2021.
Article in English | MEDLINE | ID: covidwho-1278173

ABSTRACT

INTRODUCTION: Evidence that supports the use of COVID-19 convalescent plasma (CCP) for treatment of COVID-19 is increasingly emerging. However, very few African countries have undertaken the collection and processing of CCP. The aim of this study was to assess the feasibility of collecting and processing of CCP, in preparation for a randomized clinical trial of CCP for treatment of COVID-19 in Uganda. METHODS: In a cross-sectional study, persons with documented evidence of recovery from COVID-19 in Uganda were contacted and screened for blood donation via telephone calls. Those found eligible were asked to come to the blood donation centre for further screening and consent. Whole blood collection was undertaken from which plasma was processed. Plasma was tested for transfusion transmissible infections (TTIs) and anti-SARS CoV-2 antibody titers. SARS-CoV-2 testing was also done on nasopharyngeal swabs from the donors. RESULTS: 192 participants were contacted of whom 179 (93.2%) were eligible to donate. Of the 179 eligible, 23 (12.8%) were not willing to donate and reasons given included: having no time 7(30.4%), fear of being retained at the COVID-19 treatment center 10 (43.5%), fear of stigma in the community 1 (4.3%), phobia for donating blood 1 (4.3%), religious issues 1 (4.4%), lack of interest 2 (8.7%) and transport challenges 1 (4.3%). The median age was 30 years and females accounted for 3.7% of the donors. A total of 30 (18.5%) donors tested positive for different TTIs. Antibody titer testing demonstrated titers of more than 1:320 for all the 72 samples tested. Age greater than 46 years and female gender were associated with higher titers though not statistically significant. CONCLUSION: CCP collection and processing is possible in Uganda. However, concerns about stigma and lack of time, interest or transport need to be addressed in order to maximize donations.


Subject(s)
Blood Specimen Collection/methods , COVID-19/therapy , SARS-CoV-2/isolation & purification , Adolescent , Adult , Aged , Antibodies, Viral/blood , Blood Donors , COVID-19/virology , Convalescence , Cross-Sectional Studies , Feasibility Studies , Female , Humans , Immunization, Passive/methods , Male , Middle Aged , SARS-CoV-2/immunology , SARS-CoV-2/physiology , Uganda , Young Adult , COVID-19 Serotherapy
15.
Nat Commun ; 12(1): 3695, 2021 06 17.
Article in English | MEDLINE | ID: covidwho-1275914

ABSTRACT

Serological testing is essential to curb the consequences of the COVID-19 pandemic. However, most assays are still limited to single analytes and samples collected within healthcare. Thus, we establish a multianalyte and multiplexed approach to reliably profile IgG and IgM levels against several versions of SARS-CoV-2 proteins (S, RBD, N) in home-sampled dried blood spots (DBS). We analyse DBS collected during spring of 2020 from 878 random and undiagnosed individuals from the population in Stockholm, Sweden, and use classification approaches to estimate an accumulated seroprevalence of 12.5% (95% CI: 10.3%-14.7%). This includes 5.4% of the samples being IgG+IgM+ against several SARS-CoV-2 proteins, as well as 2.1% being IgG-IgM+ and 5.0% being IgG+IgM- for the virus' S protein. Subjects classified as IgG+ for several SARS-CoV-2 proteins report influenza-like symptoms more frequently than those being IgG+ for only the S protein (OR = 6.1; p < 0.001). Among all seropositive cases, 30% are asymptomatic. Our strategy enables an accurate individual-level and multiplexed assessment of antibodies in home-sampled blood, assisting our understanding about the undiagnosed seroprevalence and diversity of the immune response against the coronavirus.


Subject(s)
Blood Specimen Collection/methods , COVID-19 Serological Testing/methods , COVID-19/immunology , Immunity, Humoral , Adult , Aged , Antibodies, Viral/immunology , COVID-19/etiology , Dried Blood Spot Testing , Female , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Male , Middle Aged , SARS-CoV-2/immunology , Sweden , Young Adult
16.
Biochem Med (Zagreb) ; 31(2): 020710, 2021 Jun 15.
Article in English | MEDLINE | ID: covidwho-1278714

ABSTRACT

INTRODUCTION: The COVID-19 pandemic has posed several challenges to clinical laboratories across the globe. Amidst the outbreak, errors occurring in the preanalytical phase of sample collection, transport and processing, can further lead to undesirable clinical consequences. Thus, this study was designed with the following objectives: (i) to determine and compare the blood specimen rejection rate of a clinical laboratory and (ii) to characterise and compare the types of preanalytical errors between the pre-pandemic and the pandemic phases. MATERIALS AND METHODS: This retrospective study was carried out in a trauma-care hospital, presently converted to COVID-19 care centre. Data was collected from (i) pre-pandemic phase: 1st October 2019 to 23rd March 2020 and (ii) pandemic phase: 24th March to 31st October 2020. Blood specimen rejection rate was calculated as the proportion of blood collection tubes with preanalytical errors out of the total number received, expressed as percentage. RESULTS: Total of 107,716 blood specimens were screened of which 43,396 (40.3%) were received during the pandemic. The blood specimen rejection rate during the pandemic was significantly higher than the pre-pandemic phase (3.0% versus 1.1%; P < 0.001). Clotted samples were the commonest source of preanalytical errors in both phases. There was a significant increase in the improperly labelled samples (P < 0.001) and samples with insufficient volume (P < 0.001), whereas, a significant decline in samples with inadequate sample-anticoagulant ratio and haemolysed samples (P < 0.001). CONCLUSION: In the ongoing pandemic, preanalytical errors and resultant blood specimen rejection rate in the clinical laboratory have significantly increased due to changed logistics. The study highlights the need for corrective steps at various levels to reduce preanalytical errors in order to optimise patient care and resource utilisation.


Subject(s)
Blood Specimen Collection/methods , COVID-19/diagnosis , Pre-Analytical Phase , Blood Specimen Collection/instrumentation , COVID-19/epidemiology , COVID-19/virology , Diagnostic Errors , Humans , Laboratories, Hospital/standards , Pandemics , Retrospective Studies , SARS-CoV-2/isolation & purification
18.
Sci Rep ; 11(1): 9475, 2021 05 04.
Article in English | MEDLINE | ID: covidwho-1216469

ABSTRACT

During August 2020, we carried out a serological survey among students and employees at the Okinawa Institute of Science and Technology Graduate University (OIST), Japan, testing for the presence of antibodies against SARS-CoV-2, the causative agent of COVID-19. We used a FDA-authorized 2-step ELISA protocol in combination with at-home self-collection of blood samples using a custom low-cost finger prick-based capillary blood collection kit. Although our survey did not find any COVID-19 seropositive individuals among the OIST cohort, it reliably detected all positive control samples obtained from a local hospital and excluded all negatives controls. We found that high serum antibody titers can persist for more than 9 months post infection. Among our controls, we found strong cross-reactivity of antibodies in samples from a serum pool from two MERS patients in the anti-SARS-CoV-2-S ELISA. Here we show that a centralized ELISA in combination with patient-based capillary blood collection using as little as one drop of blood can reliably assess the seroprevalence among communities. Anonymous sample tracking and an integrated website created a stream-lined procedure. Major parts of the workflow were automated on a liquid handler, demonstrating scalability. We anticipate this concept to serve as a prototype for reliable serological testing among larger populations.


Subject(s)
Blood Specimen Collection/methods , COVID-19 Serological Testing/methods , Antibodies, Viral/blood , Blood Specimen Collection/instrumentation , Coronavirus Infections/blood , Coronavirus Infections/immunology , Cross Reactions , Enzyme-Linked Immunosorbent Assay , Humans , Phlebotomy/methods , Reproducibility of Results , Self-Testing , Sensitivity and Specificity , Seroepidemiologic Studies , Spike Glycoprotein, Coronavirus/genetics , Spike Glycoprotein, Coronavirus/isolation & purification , Time Factors
19.
Sex Transm Infect ; 97(3): 209-214, 2021 05.
Article in English | MEDLINE | ID: covidwho-1189914

ABSTRACT

OBJECTIVES: We comparatively evaluated two HIV and syphilis blood sampling kits (dried blood spot (DBS) and mini tube (MT)) as part of an online STI postal sampling service that included tests for chlamydia and gonorrhoea. We aimed to see how the blood collection systems compared regarding sample return rates and result rates. Additionally, we aimed to observe differences in false-positive results and describe a request-to-result ratio (RRR)-the required number of kit requests needed to obtain one successful result. METHODS: We reviewed data from an online postal STI kit requesting service for a client transitioning from MT to DBS blood collection systems. We described service user baseline characteristics and compared kit requests, kit and blood sample return rates, and the successful resulting rates for HIV and syphilis for MT and DBS. Pearson's χ2 and Fisher's exact test were used to determine statistical differences, and statistical formulae were applied to produce CIs for differences in proportions. RESULTS: 5670 STI postal kit requests from a Midlands region were reviewed from 6 September 2016-2 January 2019 (1515 MT and 4155 DBS). Baseline characteristics between the two groups were comparable (68.0% female, 74.0% white British and 87.5% heterosexual, median age 26 years). Successful processing rates for DBS were 94.6% and 54.4% for MT (p<0.001) with a percentage difference of 40.2% (95% CI 36.9% to 43.4%). The RRR for MT was 2.9 cf. 1.6 for DBS. False-positive results for MT samples were 5.2% (HIV) and 0.4% (syphilis), and those for DBS were 0.4% (HIV) and 0.0% (syphilis). CONCLUSIONS: This comparative analysis demonstrated the superior successful processing rates for postal DBS collection systems compared with MT. Reasons for this included insufficient volumes, high false-positive rates and degradation of blood quality in MT samples. A postal sampling service using DBS to screen for HIV, syphilis and other blood-borne viruses could be a viable alternative.


Subject(s)
Blood Specimen Collection/methods , Dried Blood Spot Testing/methods , HIV Infections/diagnosis , Syphilis/diagnosis , Adult , Blood Specimen Collection/instrumentation , Dried Blood Spot Testing/instrumentation , False Positive Reactions , Female , HIV Infections/blood , Humans , Male , Syphilis/blood , Syphilis Serodiagnosis , Young Adult
20.
Ann Clin Biochem ; 58(5): 411-421, 2021 09.
Article in English | MEDLINE | ID: covidwho-1181016

ABSTRACT

BACKGROUND: The COVID-19 pandemic has drastically changed the delivery of secondary care services. Self-collection of capillary blood at home can facilitate the monitoring of patients with chronic disease to support virtual clinics while mitigating the risk of SARS-CoV-2 infection and transmission. OBJECTIVE: To investigate the comparability of whole blood capillary and plasma venous samples for 15 routinely used biochemical analytes and to develop and pilot a user-friendly home-collection kit to support virtual outpatient clinical services. METHODS: To investigate the comparability of whole blood capillary and plasma venous samples for 15 routinely requested biochemical analytes, simultaneous samples of venous and capillary blood were collected in EDTA and lithium-heparin plasma separation tubes that were of 4-6 mL and 400-600 µL draw volume, respectively. Venous samples were analysed within 4 h of collection while capillary samples were kept at ambient temperature for three days until centrifugation and analysis. Analyte results that were comparable between the matrices were then piloted in a feasibility study in three outpatient clinical services. RESULTS: HbA1c, lipid profile and liver function tests were considered comparable and piloted in the patient feasibility study. The home-collect kit demonstrated good patient usability. CONCLUSION: Home collection of capillary blood could be a clinically-useful tool to deliver virtual care to patients with chronic disease.


Subject(s)
Blood Chemical Analysis/methods , Blood Specimen Collection/methods , COVID-19/blood , Pandemics , SARS-CoV-2 , Adult , Blood Chemical Analysis/instrumentation , Blood Specimen Collection/instrumentation , Capillary Tubing , Feasibility Studies , Female , Humans , London , Male , Middle Aged , Phlebotomy/instrumentation , Phlebotomy/methods , Pilot Projects , Remote Consultation , Self Care/instrumentation , Self Care/methods , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL